SPECIFICATIONS
- Available temperature ranges:
- -20°F to 140°F (-28°C to 60°C).
- 20°F to 120°F (-6°C to 48°C).
- 30°F to 180°F (-1°C to 82°C).
- Temperature accurate to within ± 1.50%.
- NIST certified accurate to within ±1% from 10% to 80% relative humidity at 77°F to 95°F (25°C to 35°C).
- Uses a platinum RTD for precision temperature compensation.
- Sensing element: 1000W platinum; 2 lead resistance thermometer, .00385 TCR
- Two-point field calibration.
- Output: 4-20mA DC = 0% to 100% RH.
- Requires the ENVIROMUX-S420MA to operate.
|