SPECIFICATIONSA. PORT SPECIFICATIONS:
1. Power Port
- 110 or 230 VAC at 50 or 60 Hz via IEC connector.
- Connection for Earth Ground.
- Fuse protection.
- Optional dual power (not shown)
- 110 or 230 VAC at 50 or 60 Hz via IEC connector.
- If the first power source fails, the unit will automatically, without interruption, switch over to the second power source before switching to the battery backup.
2. RJ45 Sensor Ports
- Sixteen RJ45 modular jacks for connecting NTI temperature, humidity, temperature/humidity, liquid detection, smoke detection, glass break, vibration and motion sensors.
3. Digital Inputs
- Screw terminals.
- Input voltage: 0 V DC to +25 VDC.
- Provides +12 V DC, 50 mA.
- Fuse protection.
4. Output Relays
- Screw terminals.
- Potential-free relay switch contacts.
- Maximum switching load: 0.5A at 100VAC, 1A at 30VDC
5. Beacon Port- Screw terminals.
- Provides +12 V DC, 180 mA to supply an alarm beacon.
- Fuse protection
6. Siren Port
- Screw terminals.
- Provides +12 V DC, 130 mA to supply a siren.
- Fuse protection
7. Expansion Ports
- RJ45 connectors.
- A maximum of 4 systems can be cascaded to increase the number of sensor ports.
- Uses a single Web interface for all systems connected.
8. Console Port
- One female DB9 RS232 serial port for terminal access.
9. AUX Port
- One male DB9 RS232 serial port for controlling and monitoring external equipment, such as a GSM modem.
- GSM modems supported: Enfora GSM1218, MultiTech MTCBA-G-F2, Wavecom Fastrack M1306
10. AUX Power Port
- Provides +12 VDC, 150 mA.
- Fuse protection
11. Ethernet Port
- One 10/100 Base-T Ethernet port with RJ45 Ethernet connector.
B. OTHER SPECIFICATIONS:
Protocols
- HTTP, SNMP V1/V2c, SMTP, TCP/IP, Syslog, SNTP
- Supports local authentication, SSL.
- Operates and configures via HTTP/HTTPS web page, Telnet or RS232 interface.
- Alerts are sent using email, SMS messages and/or SNMP traps when any monitored environmental condition exceeds a user-specified range.
- Alerts are posted in message log, which is accessible through Web user interface. The log can be downloaded as a tab-delimited plain text file.
- Sends notifications of alerts to a maximum of 17 email addresses, SNMP addresses and/or cell phone numbers. The users can configure the schedule when they will be alerted
Internal Temperature Sensor
- Applications from 32°F to 104°F (0ºC to 40ºC).
- Accurate to within ±1.35°F (±0.75ºC).
Internal Humidity Sensor
- Applications from 20% to 80% relative humidity at temperatures between 32°F to 104°F (0ºC to 40ºC).
- Accurate to within ±5% relative humidity.
Internal Power Sensor
- Measures mains voltage: 0 to 255 VAC
- Measures battery voltage: 0 to 20 VDC
- Alerts are sent when there is a power outage and when power returns.
Back-up Battery
- Rechargeable sealed lead-acid battery.
- Provides back-up for one hour.
Dimensions
Environmental- Operating temperature: 32°F to 100°F (0°C to 38°C).
- Storage temperature: -22°F to 140°F (-30°C to 60°C).
- Operating and Storage Relative Humidity: 17 to 90% non-condensing RH.
Regulatory Approvals
|